SR9009 is a synthetic small molecule studied as an agonist of the nuclear receptors REV-ERBα and REV-ERBβ. It is not an approved medicine and has no established human therapeutic use. The compound appears in scientific literature as a tool for probing circadian and metabolic regulation. Online sellers often label it as a research chemical, sometimes using the nickname Stenabolic. Its chemical identity is distinct from selective androgen receptor modulators, stimulants, and peroxisome proliferator-activated receptor delta agonists. Researchers use it mainly in cell and animal experiments.

At the molecular level, SR9009 binds REV-ERBα and REV-ERBβ and alters their repressive activity on target genes. These nuclear receptors help regulate the circadian clock, lipid synthesis, glucose metabolism, and inflammatory pathways. By changing transcription, the compound can shift the timing or magnitude of downstream metabolic processes in model systems. It does not act through androgen receptors or adenosine receptors, which distinguishes it from several substances sold for athletic performance. Whether the same transcriptional changes occur in humans at tolerable exposures remains an open question because controlled human studies are lacking.

Preclinical reports describe effects on exercise endurance, mitochondrial content, and lipid profiles in rodents, but these findings come from specific experimental conditions. Many studies use high doses or delivery methods that may not translate directly to human use. SR9009 has been reported to have low oral bioavailability and a short half-life, which complicates interpretation of oral dosing studies. It is not established as safe or effective for any indication. Literature discussions often separate its pharmacological mechanism from unverified claims made in fitness and supplement markets.

Analytical Detection and Stability

Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.

Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.

Regulatory treatment of SR9009 varies by country and region. It is not approved as a pharmaceutical, and several jurisdictions restrict its sale for human consumption. Some authorities classify it as a research chemical, a prescription-only substance, or a prohibited performance-enhancing agent in sport. Purchasers may encounter certificates of analysis, but these documents do not guarantee identity, purity, or legality. In research settings, institutional safety reviews and controlled procurement help ensure that materials are handled under appropriate oversight. The absence of harmonized rules means that legal status can change and requires verification.

Sr9009 at a glance

PropertyValueNotes
Molecular formulaC20H24ClN3O4SDerived from published structure.
Molecular weight437.94 g/molCalculated value.
AppearanceWhite to off-white solidTypical for purified research samples.
SolubilityDMSO, ethanol; low in waterClass: poorly water-soluble.
Typical storage-20 °C, desiccated, protected from lightLimits degradation.

Background and Research Status

REV-ERB proteins help regulate daily cycles in gene expression, including genes tied to lipid and glucose metabolism. SR9009 binds these receptors and alters their activity in cell and animal experiments. Consequences observed in rodents include changes in skeletal muscle oxidative capacity, blood lipid levels, and exercise performance. The precise chain from receptor occupancy to whole-body effects is still an active area of study. Human responses cannot be assumed from rodent data.

Most published work on SR9009 consists of preclinical studies. It is widely sold as a research chemical, a category that does not imply safety, efficacy, or pharmaceutical-grade quality. Sports anti-doping organizations have listed SR9009 as a prohibited substance, and its presence in an athlete sample can lead to sanctions. Legal status differs by country; in several jurisdictions it is not approved for human consumption and may be treated as an unapproved new drug.

Related pages on this site

Analytical and Handling Considerations

Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.

SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.

For long-term storage, SR9009 is typically kept as a solid at low temperature, protected from moisture and light. Desiccated conditions limit hydrolysis, while opaque containers reduce photochemical breakdown. Solutions are less stable than solids and are often stored frozen in aliquots to avoid repeated freeze-thaw cycles. Stability data are not standardized across all suppliers, so users should rely on certificate-of-analysis information when available. Degradation may appear as color change, precipitate, or decreased chromatographic purity.

Supporting material

=== The efficiency of EI === Increasing the electron ionization process is done by increasing the ionization efficiency. In order to achieve higher ionization efficiency there should be an optimized filament current, emission current, and ionizing current. The current supplied to the filament to heat it to incandescent is called the filament current. The emission current is the current measured between the filament and the electron entry slit. The ionizing current is the rate of electron arrival at the trap. It is a direct measure of the number of electrons in the chamber that are available for ionization. The sample ion current (I+) is the measure of the ionization rate. This can be enhanced by manipulation of the ion extraction efficiency (β), the total ionizing cross section (Qi), the effective ionizing path length (L), the concentration of the sample molecules([N]) and the ionizing current (Ie). The equation can be shown as follows:

=== rRNA === Ψ is found in the large and small ribosomal subunits of all domains of life and their organelles. In the ribosome, Ψ residues cluster in domains II, IV, and V, and stabilize RNA-RNA and/or RNA-protein interactions. The stability afforded by Ψ may assist rRNA folding and ribosome assembly. Ψ may also influence the stability of local structures which impact the speed and accuracy of decoding and proofreading during translation.

== See also == Calorimeter Clinical chemistry Environmental chemistry Ion beam analysis List of chemical analysis methods Important publications in analytical chemistry List of materials analysis methods Measurement uncertainty Metrology Microanalysis Nuclear reaction analysis Quality of analytical results Radioanalytical chemistry Rutherford backscattering spectroscopy Sensory analysis - in the field of Food science Virtual instrumentation Working range

Sources: en.wikipedia.org

Supporting material

ISOTEC provides isotopically labeled products for protein structure determination, peptide synthesis, proteomics, metabolic research, magnetic resonance imaging, nuclear magnetic resonance, breath test substrates, agriculture, as well as gas and gas mixes.

Racemic menthol can also be formed by hydrogenation of thymol, menthone, or pulegone. In both cases with further processing (crystallizative entrainment resolution of the menthyl benzoate conglomerate) it is possible to concentrate the L-enantiomer, however this tends to be less efficient, although the higher processing costs may be offset by lower raw material costs. A further advantage of this process is that D-menthol becomes inexpensively available for use as a chiral auxiliary, along with the more usual L-antipode.

Amino acid dating is a dating technique that measures ratios of amino acid isomers in fossils to determine their age. Amino acid dating cannot produce numerical age estimates on its own, requiring site-specific calibration from other dating methods, but it is relatively cheap. The preserved protein needed to perform this analysis is most easily found in shell-bearing organisms, and so this technique is often used in the investigation of ocean sediments.

The reaction has the important effect of converting the cofactor, nicotinamide adenine dinucleotide in its reduced form, into its oxidised counterpart NAD+. Isothermal titration calorimetry (ITR), nuclear magnetic resonance (NMR) crystallography, and clonal studies of OcDH and its substrates have led to the identification of the enzyme reaction mechanism. First, the Rossmann fold in Domain I of OcDH binds NADH. Binding of NADH to the Rossmann fold triggers small conformational change typical in the binding of NADH to most dehydrogenases resulting in an interaction between the pyrophosphate moiety of NADH with residue Arg324 on Domain II. This interaction with Arg324 generates and stabilizes the L-arginine binding site and triggers partial domain closure (reduction in the distance between the two domains). The binding of the guanidinium headgroup of L-arginine to the active site of the OcDH:NADH complex (located between the domains) induces a rotational movement of Domain II towards Domain I (via a helix-kink-helix structure in Domain II). This conformational change forms the pyruvate binding site. Binding of pyruvate to the OcDH:NADH:L-arginine complex places the alpha-ketogroup of pyruvate in proximity with the alpha-amino group of L-arginine. The juxtaposition of these groups on the substrates results in the formation of a Schiff base which is subsequently reduced to D-octopine. The priming of the pyruvate site for hydride transfer via a Schiff base through the sequential binding of NADH and L-arginine to OcDH prevents the reduction of pyruvate to lactate.

Sources: en.wikipedia.org

Frequently asked questions

What is SR9009?

SR9009 is a synthetic REV-ERB agonist used in laboratory research. It is not an approved drug, and its effects in humans are not well characterized. It is often sold as a research chemical under the name Stenabolic.

Is SR9009 a SARM?

No. SR9009 targets the nuclear receptors REV-ERBα and REV-ERBβ, not the androgen receptor. This mechanism differs from selective androgen receptor modulators and from exercise mimetics that act on PPARδ.

Are there human trials of SR9009?

Published evidence is mainly preclinical, using cell cultures and animal models. Controlled human trials are not well documented in the public literature. Claims about human performance or health effects therefore remain unsupported by robust clinical data.

How is SR9009 measured in samples?

The most common approach is liquid chromatography-tandem mass spectrometry, often after extraction from blood, urine, or tissue. Ultraviolet detection and nuclear magnetic resonance spectroscopy are used mainly for reference material characterization. Isotope-labeled internal standards improve accuracy.